Technical Parameters:
Working PowerRange : DC(8-35)V
Overall Dimension : 242*186*53
Installation Dimension : 214*160
Working Temperature : (-40~+70)℃
weight : 0.85kg


Product Overview:
HGM8100Z series genset controllers are designed especially for extremely high/low temperature environment (-40~+70)°C. The controllers can operate reliably in extreme temperature conditions with the help of heatable LCD and the electronic components that withstand extreme temperature. The controllers have strong electromagnetic compatibility, and can run normally under complex environment with intense electromagnetic interference. It is easy to maintain and upgrade due to the plug-in terminals. The language options are Chinese, English and other languages.

HGM8100Z series genset controllers integrate digital, intelligent and network technology. They are used for automation and monitor control system of single genset to achieve automatic start/stop, data measurement, alarm protection and “Three Remote” functions (remote control, remote measuring and remote communication). The controllers adopt 32-bit microprocessor to realize precise parameters measuring, fixed value adjustment, time setting and threshold setting, etc. Major parameters can be configured directly from front panel, and all parameters can be configured by PC via USB interface, or adjusted and monitored via RS485 and ETHERNET interface. It can be widely used in all types of automatic genset control system with compact structure, easy wiring connection and high reliability


PERFORMANCE AND FEATURES
HGM8110Z: It is used for automation system of single genset, and can control genset auto start/stop through remote start signal.
HGM8120Z: Based on HGM8110Z, it adds AMF (Auto Mains Failure) function and automatic transfer function for mains and generator, especially for the single genset automatic system of mains and one genset.

Main features are as below:
1) With 32-bit microprocessor, it has higher integration density and operation reliability;
2) Large size of graphic dot matrix LCD screen (it can be heated according to the environment temperature), optional Chinese/English interface which can be set on the site, making commissioning convenient for factory personnel;
3) The protection layer of LCD screen uses hard acrylic material with good abrasion-resistant and scratch-resistant performance;
4) Silicone front panel and pushbuttons can be used in extreme temperature environment;
5) With RS485 and RS232 communication interfaces, it can realize “Three Remote” functions (remote control, remote measuring and remote communication) under MODBUS protocol;
6) WithEthernet communication interface, it can realize monitoring function;
7) With CANBUS port, it can connect to the J1939 genset. It can not only monitor frequently-used data (such as water temperature, oil pressure, speed, fuel consumption, etc.) of ECU engine, but also control the start, stop, speed rise and droop via CANBUS port;
8) Suitable for 3-phase 4-wire, 3-phase 3-wire, single phase 2-wire, and 2-phase 3-wire AC systems with voltage of 120/240V AC and frequency of 50/60Hz;
9) It can collect and show 3-phase voltage, current, frequency and power parameter of mains or generator;
10) For Mains, the controller has over/under voltage, over/under frequency, loss of phase and reverse phase sequence detection functions; for generator, it has over/under voltage, over/under frequency, over current, over/reverse power, loss of phase, and reverse phase sequence functions;
11) 3 fixed analog sensors (temperature, oil pressure and fuel level);
12) 2 configurable analog sensors can be set as sensor of temperature, pressure or level;
13) It can measure and display various engine parameters
14) Control and protection functions: automatic start/stop of the genset, ATS (Auto Transfer Switch) control, clear fault alarm and protection function;
15) All output ports are relay type;
16) Parameter setting: parameters can be modified by users. They will be stored in internal FLASH memory and won’t be lost even in case of power outage; most of them can be adjusted on the front panel of the controller and all of them can be modified by PC via USB, RS485 or ETHERNET ports;
17) Various kinds of sensor curves of temperature, pressure, fuel level can be used directly and users can self-define the sensor curves;
18) Multiple options of crank disconnection condition (speed, oil pressure, generator frequency);
19) Wide power supply range of (8~35)V DC, which is suitable for different voltages of starting battery;
20) Functions of event log, real-time clock, and scheduled start & stop (the genset start frequency can be set as once a day/week/month whether with load or not);
21) PLC (Programmable Logic Control) function. Users can use graphical programming to achieve specific functions;
22) It can be used on pump units or as an indication instrument (indicate and alarm are enabled only, relay is inhibited);
23) With maintenance function,